RFC 305 UNKNOWN NETWORK · OPERATIONS · IMP

Unknown Host Numbers

Why temporary IMP tests can produce unfamiliar host numbers

On rfc-editor.org ↗
PUBLISHED
February 1972
AUTHORS
R. Alter
STREAM
Legacy
DOI
10.17487/RFC0305

RFC text

Original text · RFC Editor View on rfc-editor.org ↗
Network Working Group                            Ralph Alter
RFC #305                                         BBN
NIC #9078                                        23 February 1972


                          UNKNOWN HOST NUMBERS
                          --------------------

   In response to a recent minor flurry of confusion, it seems worth
   announcing publicly the fact that new IMPs are tested (almost
   always) on the ARPA Net here at BBN before delivery to the intended
   site.  Accordingly, sites should not be surprised to receive RFCs
   or at least RSTs from IMPs or Hosts they thought didn't exist, or
   at least did not exist yet.

   Occasionally, IMPs of some given configuration are tested in a
   mode where they announce their IMP number as different from what
   it will be when finally installed.  A variety of reasons may create
   such a situation.  The latest such occurrence is that a TIP, to be
   installed shortly at ETAC with IMP number 20 (replacing the 316
   IMP now at ETAC which is number 20) was recently tested here with
   McClellan's IMP number (22).  (It couldn't be tested with its own
   number since the 316 IMP currently at ETAC is using that number.)
   The result was RSTs from the TIP (Host 3) at IMP 22 - which is
   network address 150 (226 octal or 96 hex).

   One site asked if their Host tables needed updating.  The answer
   is _NO_.  We fully expect IMPs tested under these circumstances to be
   ignored or CLS'd by some Hosts.  We suggest that Host tables (where
   they are thought to be necessary) be modified only in response to
   official notification from BBN via either an RFC or an update to
   Appendix A of BBN Report #1822.


   RA/jm

       [ This RFC was put into machine readable form for entry ]
       [ into the online RFC archives by BBN Corp. under the   ]
       [ direction of Alex McKenzie.                   12/96   ]

ISO Plain Language

On this page
PROBLEMNetwork sites may see reset messages from an IMP or host whose number they do not recognize.
MECHANISMBBN explains that it tests new IMPs on the ARPANET before delivery, sometimes using a temporary number already assigned elsewhere.
WHAT SITES SHOULD DOSites should not change host tables for these tests; BBN says to wait for official notice before making such changes.

§1Testing New IMPs on the Network

BBN says that it almost always tested new IMPs on the ARPANET before delivering them to their intended sites. As a result, a site might receive a connection request or reset message from an IMP or host it did not expect to exist yet.

BBN tested new network equipment before shipping it to its assigned site. Other sites could see messages from that equipment during the test.

§2Temporary Numbers During Testing

A test IMP could announce a number different from the number planned for its permanent installation. The example is a TIP intended for ETAC, where IMP number 20 was already in use. BBN tested it as number 22, which produced reset messages with network address 150.

The temporary number explained why the messages did not match the official host information.

A test unit could use a number that belonged to another site because its final number was already in use. That could make its network messages look unfamiliar.

§3When to Change Host Tables

BBN answers that sites do not need to update their host tables because of these test messages. Hosts may ignore or close connections from test IMPs. The notice says host tables should be changed only after official notification from BBN, either through an RFC or an update to Appendix A of BBN Report 1822.

Do not change a host table just because a test unit sends a message. Wait for BBN's official notice before changing it.