Protection benchmarking: Benchmarking Terminology for Protection Performance
The shared vocabulary for measuring how fast a network switches traffic to a backup route when something fails.
Poretsky, S., Papneja, R., Karthik, J., and S. Vapiwala, "Benchmarking Terminology for Protection Performance", RFC 6414, DOI 10.17487/RFC6414, November 2011, <https://www.rfc-editor.org/info/rfc6414>.
@misc{rfc6414,
series = {Request for Comments},
number = 6414,
howpublished = {RFC 6414},
publisher = {RFC Editor},
doi = {10.17487/RFC6414},
url = {https://www.rfc-editor.org/info/rfc6414},
author = {S. Poretsky and R. Papneja and J. Karthik and S. Vapiwala},
title = {{Benchmarking Terminology for Protection Performance}},
pagetotal = 33,
year = 2011,
month = nov,
} RFC text
Contents
Internet Engineering Task Force (IETF) S. Poretsky
Request for Comments: 6414 Allot Communications
Category: Informational R. Papneja
ISSN: 2070-1721 Huawei
J. Karthik
S. Vapiwala
Cisco Systems
November 2011
Benchmarking Terminology for Protection Performance
Abstract
This document provides common terminology and metrics for
benchmarking the performance of sub-IP layer protection mechanisms.
The performance benchmarks are measured at the IP layer; protection
may be provided at the sub-IP layer. The benchmarks and terminology
can be applied in methodology documents for different sub-IP layer
protection mechanisms such as Automatic Protection Switching (APS),
Virtual Router Redundancy Protocol (VRRP), Stateful High Availability
(HA), and Multiprotocol Label Switching Fast Reroute (MPLS-FRR).
Status of This Memo
This document is not an Internet Standards Track specification; it is
published for informational purposes.
This document is a product of the Internet Engineering Task Force
(IETF). It represents the consensus of the IETF community. It has
received public review and has been approved for publication by the
Internet Engineering Steering Group (IESG). Not all documents
approved by the IESG are a candidate for any level of Internet
Standard; see Section 2 of RFC 5741.
Information about the current status of this document, any errata,
and how to provide feedback on it may be obtained at
http://www.rfc-editor.org/info/rfc6414.
Copyright Notice
Copyright (c) 2011 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with respect
to this document. Code Components extracted from this document must
include Simplified BSD License text as described in Section 4.e of
the Trust Legal Provisions and are provided without warranty as
described in the Simplified BSD License.
This document may contain material from IETF Documents or IETF
Contributions published or made publicly available before November
10, 2008. The person(s) controlling the copyright in some of this
material may not have granted the IETF Trust the right to allow
modifications of such material outside the IETF Standards Process.
Without obtaining an adequate license from the person(s) controlling
the copyright in such materials, this document may not be modified
outside the IETF Standards Process, and derivative works of it may
not be created outside the IETF Standards Process, except to format
it for publication as an RFC or to translate it into languages other
than English.
Table of Contents
1. Introduction ....................................................4
1.1. Scope ......................................................4
1.2. General Model ..............................................5
2. Existing Definitions ............................................8
3. Test Considerations .............................................9
3.1. Paths ......................................................9
3.1.1. Path ................................................9
3.1.2. Working Path .......................................10
3.1.3. Primary Path .......................................10
3.1.4. Protected Primary Path .............................11
3.1.5. Backup Path ........................................11
3.1.6. Standby Backup Path ................................12
3.1.7. Dynamic Backup Path ................................12
3.1.8. Disjoint Paths .....................................13
3.1.9. Point of Local Repair (PLR) ........................13
3.1.10. Shared Risk Link Group (SRLG) .....................14
3.2. Protection ................................................14
3.2.1. Link Protection ....................................14
3.2.2. Node Protection ....................................15
3.2.3. Path Protection ....................................15
3.2.4. Backup Span ........................................16
3.2.5. Local Link Protection ..............................16
3.2.6. Redundant Node Protection ..........................17
3.2.7. State Control Interface ............................17
3.2.8. Protected Interface ................................18
3.3. Protection Switching ......................................18
3.3.1. Protection-Switching System ........................18
3.3.2. Failover Event .....................................19
3.3.3. Failure Detection ..................................19
3.3.4. Failover ...........................................20
3.3.5. Restoration ........................................20
3.3.6. Reversion ..........................................21
3.4. Nodes .....................................................22
3.4.1. Protection-Switching Node ..........................22
3.4.2. Non-Protection-Switching Node ......................22
3.4.3. Headend Node .......................................23
3.4.4. Backup Node ........................................23
3.4.5. Merge Node .........................................24
3.4.6. Primary Node .......................................24
3.4.7. Standby Node .......................................25
3.5. Benchmarks ................................................26
3.5.1. Failover Packet Loss ...............................26
3.5.2. Reversion Packet Loss ..............................26
3.5.3. Failover Time ......................................27
3.5.4. Reversion Time .....................................27
3.5.5. Additive Backup Delay ..............................28
3.6. Failover Time Calculation Methods .........................28
3.6.1. Time-Based Loss Method (TBLM) ......................29
3.6.2. Packet-Loss-Based Method (PLBM) ....................29
3.6.3. Timestamp-Based Method (TBM) .......................30
4. Security Considerations ........................................31
5. References .....................................................32
5.1. Normative References ......................................32
5.2. Informative References ....................................32
6. Acknowledgments ................................................32
1. Introduction
The IP network layer provides route convergence to protect data
traffic against planned and unplanned failures in the Internet. Fast
convergence times are critical to maintain reliable network
connectivity and performance. Convergence Events [6] are recognized
at the IP Layer so that Route Convergence [6] occurs. Technologies
that function at sub-IP layers can be enabled to provide further
protection of IP traffic by providing the failure recovery at the
sub-IP layers so that the outage is not observed at the IP layer.
Such sub-IP protection technologies include, but are not limited to,
High Availability (HA) stateful failover, Virtual Router Redundancy
Protocol (VRRP) [8], Automatic Link Protection (APS) for SONET/SDH,
Resilient Packet Ring (RPR) for Ethernet, and Fast Reroute for
Multiprotocol Label Switching (MPLS-FRR) [9].
1.1. Scope
Benchmarking terminology was defined for IP-layer convergence in [6].
Different terminology and methodologies specific to benchmarking sub-
IP layer protection mechanisms are required. The metrics for
benchmarking the performance of sub-IP protection mechanisms are
measured at the IP layer, so that the results are always measured in
reference to IP and independent of the specific protection mechanism
being used. The purpose of this document is to provide a single
terminology for benchmarking sub-IP protection mechanisms.
A common terminology for sub-IP layer protection mechanism
benchmarking enables different implementations of a protection
mechanism to be benchmarked and evaluated. In addition,
implementations of different protection mechanisms can be benchmarked
and evaluated. It is intended that there can exist unique
methodology documents for each sub-IP protection mechanism based upon
this common terminology document. The terminology can be applied to
methodologies that benchmark sub-IP protection mechanism performance
with a single stream of traffic or multiple streams of traffic. The
traffic flow may be unidirectional or bidirectional as to be
indicated in the methodology.
1.2. General Model
The sequence of events to benchmark the performance of sub-IP
protection mechanisms is as follows:
1. Failover Event - Primary Path fails
2. Failure Detection - Failover Event is detected
3. Failover - Backup Path becomes the Working Path due to Failover
Event
4. Restoration - Primary Path recovers from a Failover Event
5. Reversion (optional) - Primary Path becomes the Working Path
These terms are further defined in this document.
Figures 1 through 5 show models that MAY be used when benchmarking
sub-IP protection mechanisms, which MUST use a Protection-Switching
System that consists of a minimum of two Protection-Switching Nodes,
an Ingress Node known as the Headend Node and an Egress Node known as
the Merge Node. The Protection-Switching System MUST include either
a Primary Path and Backup Path, as shown in Figures 1 through 4, or a
Primary Node and Standby Node, as shown in Figure 5. A Protection-
Switching System may provide link protection, node protection, path
protection, local link protection, and high availability, as shown in
Figures 1 through 5, respectively. A Failover Event occurs along the
Primary Path or at the Primary Node. The Working Path is the Primary
Path prior to the Failover Event and the Backup Path after the
Failover Event. A Tester is set outside the two paths or nodes as it
sends and receives IP traffic along the Working Path. The tester
MUST record the IP packet sequence numbers, departure time, and
arrival time so that the metrics of Failover Time, Additive Latency,
Packet Reordering, Duplicate Packets, and Reversion Time can be
measured. The Tester may be a single device or a test system. If
Reversion is supported, then the Working Path is the Primary Path
after Restoration (Failure Recovery) of the Primary Path.
Link Protection, as shown in Figure 1, provides protection when a
Failover Event occurs on the link between two nodes along the Primary
Path. Node Protection, as shown in Figure 2, provides protection
when a Failover Event occurs at a Node along the Primary Path. Path
Protection, as shown in Figure 3, provides protection for link or
node failures for multiple hops along the Primary Path. Local Link
Protection, as shown in Figure 4, provides sub-IP protection of a
link between two nodes, without a Backup Node. An example of such a
sub-IP protection mechanism is SONET APS. High Availability
Protection, as shown in Figure 5, provides protection of a Primary
Node with a redundant Standby Node. State Control is provided
between the Primary and Standby Nodes. Failure of the Primary Node
is detected at the sub-IP layer to force traffic to switch to the
Standby Node, which has state maintained for zero or minimal packet
loss.
+-----------+
+--------------| Tester |<-----------------------+
| +-----------+ |
| IP Traffic | Failover IP Traffic |
| | Event |
| ------------ | ---------- |
+--->| Ingress/ | V | Egress/ |---+
|Headend Node|------------------|Merge Node| Primary
------------ ---------- Path
| ^
| --------- | Backup
+--------| Backup |-------------+ Path
| Node |
---------
Figure 1. System Under Test (SUT) for Sub-IP Link Protection
+-----------+
+--------------------| Tester |<-----------------+
| +-----------+ |
| IP Traffic | Failover IP Traffic |
| | Event |
| V |
| ------------ -------- ---------- |
+--->| Ingress/ | |Midpoint| | Egress/ |---+
|Headend Node|----| Node |----|Merge Node| Primary
------------ -------- ---------- Path
| ^
| --------- | Backup
+--------| Backup |-------------+ Path
| Node |
---------
Figure 2. System Under Test (SUT) for Sub-IP Node Protection
+-----------+
+---------------------------| Tester |<----------------------+
| +-----------+ |
| IP Traffic | Failover IP Traffic |
| | Event |
| Primary Path | |
| ------------ -------- | -------- ---------- |
+--->| Ingress/ | |Midpoint| V |Midpoint| | Egress/ |---+
|Headend Node|----| Node |---| Node |---|Merge Node|
------------ -------- -------- ----------
| ^
| --------- -------- | Backup
+--------| Backup |----| Backup |--------+ Path
| Node | | Node |
--------- --------
Figure 3. System Under Test (SUT) for Sub-IP Path Protection
+-----------+
+--------------------| Tester |<-------------------+
| +-----------+ |
| IP Traffic | Failover IP Traffic |
| | Event |
| Primary | |
| +--------+ Path v +--------+ |
| | |------------------------>| | |
+--->| Ingress| | Egress |----+
| Node |- - - - - - - - - - - - >| Node |
+--------+ Backup Path +--------+
| |
| IP-Layer Forwarding |
+<----------------------------------------->+
Figure 4. System Under Test (SUT) for Sub-IP Local Link Protection
+-----------+
+-----------------| Tester |<--------------------+
| +-----------+ |
| IP Traffic | Failover IP Traffic |
| | Event |
| V |
| --------- -------- ---------- |
+--->| Ingress | |Primary | | Egress/ |------+
| Node |----| Node |----|Merge Node| Primary
--------- -------- ---------- Path
| State |Control ^
| Interface |(Optional) |
| --------- |
+---------| Standby |---------+
| Node |
---------
Figure 5. System Under Test (SUT)
for Sub-IP Redundant Node Protection
Some protection-switching technologies may use a series of steps that
differ from the general model. The specific differences SHOULD be
highlighted in each technology-specific methodology. Note that some
protection-switching technologies are endowed with the ability to re-
optimize the working path after a node or link failure.
2. Existing Definitions
This document uses existing terminology defined in other BMWG work.
Examples include, but are not limited to:
Latency [2], Section 3.8
Frame Loss Rate [2], Section 3.6
Throughput [2], Section 3.17
Device Under Test (DUT) [3], Section 3.1.1
System Under Test (SUT) [3], Section 3.1.2
Offered Load [3], Section 3.5.2
Out-of-order Packet [4], Section 3.3.4
Duplicate Packet [4], Section 3.3.5
Forwarding Delay [4], Section 3.2.4
Jitter [4], Section 3.2.5
Packet Loss [6], Section 3.5
Packet Reordering [7], Section 3.3
This document has the following frequently used acronyms:
DUT Device Under Test
SUT System Under Test
This document adopts the definition format in Section 2 of RFC 1242
[2]. Terms defined in this document are capitalized when used within
this document.
The keywords "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
document are to be interpreted as described in BCP 14, RFC 2119 [5].
RFC 2119 defines the use of these keywords to help make the intent of
Standards Track documents as clear as possible. While this document
uses these keywords, this document is not a Standards Track document.
3. Test Considerations
3.1. Paths
3.1.1. Path
Definition:
A unidirectional sequence of nodes <R1, ..., Rn> and links
<L12,... L(n-1)n> with the following properties:
a. R1 is the ingress node and forwards IP packets, which input
into DUT/SUT, to R2 as sub-IP frames over link L12.
b. Ri is a node which forwards data frames to R(i+1) over Link
Li(i+1) for all i, 1<i<n-1, based on information in the sub-IP
layer.
c. Rn is the egress node, and it outputs sub-IP frames from
DUT/SUT as IP packets. L(n-1)n is the link between the R(n-1)
and Rn.
Discussion:
The path is defined in the sub-IP layer in this document, unlike
an IP path in RFC 2026 [1]. One path may be regarded as being
equivalent to one IP link between two IP nodes, i.e., R1 and Rn.
The two IP nodes may have multiple paths for protection. A packet
will travel on only one path between the nodes. Packets belonging
to a microflow [10] will traverse one or more paths. The path is
unidirectional. For example, the link between R1 and R2 in the
direction from R1 to R2 is L12. For traffic flowing in the
reverse direction from R2 to R1, the link is L21. Example paths
are the SONET/SDH path and the label switched path for MPLS.
Measurement Units:
n/a
Issues:
"A bidirectional path", which transmits traffic in both directions
along the same nodes, consists of two unidirectional paths.
Therefore, the two unidirectional paths belonging to "one
bidirectional path" will be treated independently when
benchmarking for "a bidirectional path".
See Also:
Working Path
Primary Path
Backup Path
3.1.2. Working Path
Definition:
The path that the DUT/SUT is currently using to forward packets.
Discussion:
A Primary Path is the Working Path before occurrence of a Failover
Event. A Backup Path shall become the Working Path after a
Failover Event.
Measurement Units:
n/a
Issues:
None.
See Also:
Path
Primary Path
Backup Path
3.1.3. Primary Path
Definition:
The preferred point-to-point path for forwarding traffic between
two or more nodes.
Discussion:
The Primary Path is the Path that traffic traverses prior to a
Failover Event.
Measurement Units:
n/a
Issues:
None.
See Also:
Path
Failover Event
3.1.4. Protected Primary Path
Definition:
A Primary Path that is protected with a Backup Path.
Discussion:
A Protected Primary Path must include at least one Protection-
Switching Node.
Measurement Units:
n/a
Issues:
None.
See Also:
Path
Primary Path
3.1.5. Backup Path
Definition:
A path that exists to carry data traffic only if a Failover Event
occurs on a Primary Path.
Discussion:
The Backup Path shall become the Working Path upon a Failover
Event. A Path may have one or more Backup Paths. A Backup Path
may protect one or more Primary Paths. There are various types of
Backup Paths:
a. dedicated recovery Backup Path (1+1) or (1:1), which has 100%
redundancy for a specific ordinary path
b. shared Backup Path (1:N), which is dedicated to the protection
for more than one specific Primary Path
c. associated shared Backup Path (M:N) for which a specific set of
Backup Paths protects a specific set of more than one Primary
Path
A Backup Path may be signaled or unsignaled. The Backup Path must
be created prior to the Failover Event. The Backup Path generally
originates at the point of local repair (PLR) and terminates at a
node along a primary path.
Measurement Units:
n/a
Issues:
None.
See Also:
Path
Working Path
Primary Path
3.1.6. Standby Backup Path
Definition:
A Backup Path that is established prior to a Failover Event to
protect a Primary Path.
Discussion:
The Standby Backup Path and Dynamic Backup Path provide
protection, but are established at different times.
Measurement Units:
n/a
Issues:
None.
See Also:
Backup Path
Primary Path
Failover Event
3.1.7. Dynamic Backup Path
Definition:
A Backup Path that is established upon occurrence of a Failover
Event.
Discussion:
The Standby Backup Path and Dynamic Backup Path provide
protection, but are established at different times.
Measurement Units:
n/a
Issues:
None.
See Also:
Backup Path
Standby Backup Path
Failover Event
3.1.8. Disjoint Paths
Definition:
A pair of paths that do not share a common link or nodes.
Discussion:
Two paths are disjoint if they do not share a common node or link
other than the ingress and egress.
Measurement Units:
n/a
Issues:
None.
See Also:
Path
Primary Path
SRLG
3.1.9. Point of Local Repair (PLR)
Definition:
A node capable of Failover along the Primary Path that is also the
ingress node for the Backup Path to protect another node or link.
Discussion:
Any node along the Primary Path from the ingress node to the
penultimate node may be a PLR. The PLR may use a single Backup
Path for protecting one or more Primary Paths. There can be
multiple PLRs along a Primary Path. The PLR must be an ingress to
a Backup Path. The PLR can be any node along the Primary Path
except the egress node of the Primary Path. The PLR may
simultaneously be a Headend Node when it is serving the role as
ingress to the Primary Path and the Backup Path. If the PLR is
also the Headend Node, then the Backup Path is a Disjoint Path
from the ingress to the Merge Node.
Measurement Units:
n/a
Issues:
None.
See Also:
Primary Path
Backup Path
Failover
3.1.10. Shared Risk Link Group (SRLG)
Definition:
SRLG is a set of links that share the same risk (physical or
logical) within a network.
Discussion:
SRLG is considered the set of links to be avoided when the primary
and secondary paths are considered disjoint. The SRLG will fail
as a group if the shared resource (physical or anything abstract
such as software version) fails.
Measurement Units:
n/a
Issues:
None.
See Also:
Path Primary Path
3.2. Protection
3.2.1. Link Protection
Definition:
A Backup Path that is signaled to at least one Backup Node to
protect for failure of interfaces and links along a Primary Path.
Discussion:
Link Protection may or may not protect the entire Primary Path.
Link Protection is shown in Figure 1.
Measurement Units:
n/a
Issues:
None.
See Also:
Primary Path Backup Path
3.2.2. Node Protection
Definition:
A Backup Path that is signaled to at least one Backup Node to
protect for failure of interfaces, links, and nodes along a
Primary Path.
Discussion:
Node Protection may or may not protect the entire Primary Path.
Node Protection also provides Link Protection. Node Protection is
shown in Figure 2.
Measurement Units:
n/a
Issues:
None.
See Also:
Link Protection
3.2.3. Path Protection
Definition:
A Backup Path that is signaled to at least one Backup Node to
provide protection along the entire Primary Path.
Discussion:
Path Protection provides Node Protection and Link Protection for
every node and link along the Primary Path. A Backup Path
providing Path Protection may have the same ingress node as the
Primary Path. Path Protection is shown in Figure 3.
Measurement Units:
n/a
Issues:
None.
See Also:
Primary Path
Backup Path
Node Protection
Link Protection
3.2.4. Backup Span
Definition:
The number of hops used by a Backup Path.
Discussion:
The Backup Span is an integer obtained by counting the number of
nodes along the Backup Path.
Measurement Units:
number of nodes
Issues:
None.
See Also:
Primary Path
Backup Path
3.2.5. Local Link Protection
Definition:
A Backup Path that is a redundant path between two nodes and does
not use a Backup Node.
Discussion:
Local Link Protection must be provided as a Backup Path between
two nodes along the Primary Path without the use of a Backup Node.
Local Link Protection is provided by Protection-Switching Systems
such as SONET APS. Local Link Protection is shown in Figure 4.
Measurement Units:
n/a
Issues:
None.
See Also:
Backup Path
Backup Node
3.2.6. Redundant Node Protection
Definition:
A Protection-Switching System with a Primary Node protected by a
Standby Node along the Primary Path.
Discussion:
Redundant Node Protection is provided by Protection-Switching
Systems such as VRRP and HA. The protection mechanisms occur at
sub-IP layers to switch traffic from a Primary Node to Backup Node
upon a Failover Event at the Primary Node. Traffic continues to
traverse the Primary Path through the Standby Node. The failover
may be stateful, in which the state information may be exchanged
in-band or over an out-of-band State Control Interface. The
Standby Node may be active or passive. Redundant Node Protection
is shown in Figure 5.
Measurement Units:
n/a
Issues:
None.
See Also:
Primary Path
Primary Node
Standby Node
3.2.7. State Control Interface
Definition:
An out-of-band control interface used to exchange state
information between the Primary Node and Standby Node.
Discussion:
The State Control Interface may be used for Redundant Node
Protection. The State Control Interface should be out-of-band.
It is possible to have Redundant Node Protection in which there is
no state control or state control is provided in-band. The State
Control Interface between the Primary and Standby Node may be one
or more hops.
Measurement Units:
n/a
Issues:
None.
See Also:
Primary Node
Standby Node
3.2.8. Protected Interface
Definition:
An interface along the Primary Path that is protected by a Backup
Path.
Discussion:
A Protected Interface is an interface protected by a Protection-
Switching System that provides Link Protection, Node Protection,
Path Protection, Local Link Protection, and Redundant Node
Protection.
Measurement Units:
n/a
Issues:
None.
See Also:
Primary Path
Backup Path
3.3. Protection Switching
3.3.1. Protection-Switching System
Definition:
A DUT/SUT that is capable of Failure Detection and Failover from a
Primary Path to a Backup Path or Standby Node when a Failover
Event occurs.
Discussion:
The Protection-Switching System must include either a Primary Path
and Backup Path, as shown in Figures 1 through 4, or a Primary
Node and Standby Node, as shown in Figure 5. The Backup Path may
be a Standby Backup Path or a Dynamic Backup Path. The
Protection-Switching System includes the mechanisms for both
Failure Detection and Failover.
Measurement Units:
n/a
Issues:
None.
See Also:
Primary Path Backup Path Failover
3.3.2. Failover Event
Definition:
The occurrence of a planned or unplanned action in the network
that results in a change in the Path that data traffic traverses.
Discussion:
Failover Events include, but are not limited to, link failure and
router failure. Routing changes are considered Convergence Events
[6] and are not Failover Events. This restricts Failover Events
to sub-IP layers. Failover may be at the PLR or at the ingress.
If the failover is at the ingress, it is generally on a disjoint
path from the ingress to egress.
Failover Events may result from failures such as link failure or
router failure. The change in path after Failover may have a
Backup Span of one or more nodes. Failover Events are
distinguished from routing changes and Convergence Events [6] by
the detection of the failure and subsequent protection switching
at a sub-IP layer. Failover occurs at a PLR or Primary Node.
Measurement Units:
n/a
Issues:
None.
See Also:
Path
Failure Detection
Disjoint Path
3.3.3. Failure Detection
Definition:
The process to identify at a sub-IP layer a Failover Event at a
Primary Node or along the Primary Path.
Discussion:
Failure Detection occurs at the Primary Node or ingress node of
the Primary Path. Failure Detection occurs via a sub-IP mechanism
such as detection of a link down event or timeout for receipt of a
control packet. A failure may be completely isolated. A failure
may affect a set of links that share a single SRLG (e.g., port
with many sub-interfaces). A failure may affect multiple links
that are not part of the SRLG.
Measurement Units:
n/a
Issues:
None.
See Also:
Primary Path
3.3.4. Failover
Definition:
The process to switch data traffic from the protected Primary Path
to the Backup Path upon Failure Detection of a Failover Event.
Discussion:
Failover to a Backup Path provides Link Protection, Node
Protection, or Path Protection. Failover is complete when Packet
Loss [6], Out-of-order Packets [4], and Duplicate Packets [4] are
no longer observed. Forwarding Delay [4] may continue to be
observed.
Measurement Units:
n/a
Issues:
None.
See Also:
Primary Path Backup Path Failover Event
3.3.5. Restoration
Definition:
The state of failover recovery in which the Primary Path has
recovered from a Failover Event, but is not yet forwarding packets
because the Backup Path remains the Working Path.
Discussion:
Restoration must occur while the Backup Path is the Working Path.
The Backup Path is maintained as the Working Path during
Restoration. Restoration produces a Primary Path that is
recovered from failure, but is not yet forwarding traffic.
Traffic is still being forwarded by the Backup Path functioning as
the Working Path.
Measurement Units:
n/a
Issues:
None.
See Also:
Primary Path
Failover Event
Failure Recovery
Working Path
Backup Path
3.3.6. Reversion
Definition:
The state of failover recovery in which the Primary Path has
become the Working Path so that it is forwarding packets.
Discussion:
Protection-Switching Systems may or may not support Reversion.
Reversion, if supported, must occur after Restoration. Packet
forwarding on the Primary Path resulting from Reversion may occur
either fully or partially over the Primary Path. A potential
problem with Reversion is the discontinuity in end-to-end delay
when the Forwarding Delays [4] along the Primary Path and Backup
Path are different, possibly causing Out-of-order Packets [4],
Duplicate Packets [4], and increased Jitter [4].
Measurement Units:
n/a
Issues:
None.
See Also:
Protection-Switching System
Working Path
Primary Path
3.4. Nodes
3.4.1. Protection-Switching Node
Definition:
A node that is capable of participating in a Protection Switching
System.
Discussion:
The Protection-Switching Node may be an ingress or egress for a
Primary Path or Backup Path, such as used for MPLS Fast Reroute
configurations. The Protection-Switching Node may provide
Redundant Node Protection as a Primary Node in a Redundant chassis
configuration with a Standby Node, such as used for VRRP and HA
configurations.
Measurement Units:
n/a
Issues:
None.
See Also:
Protection-Switching System
3.4.2. Non-Protection-Switching Node
Definition:
A node that is not capable of participating in a Protection
Switching System, but may exist along the Primary Path or Backup
Path.
Discussion:
None.
Measurement Units:
n/a
Issues:
None.
See Also:
Protection-Switching System
Primary Path
Backup Path
3.4.3. Headend Node
Definition:
The ingress node of the Primary Path.
Discussion:
The Headend Node may also be a PLR when it is serving in the dual
role as the ingress to the Backup Path.
Measurement Units:
n/a
Issues:
None.
See Also:
Primary Path
PLR
Failover
3.4.4. Backup Node
Definition:
A node along the Backup Path.
Discussion:
The Backup Node can be any node along the Backup Path. There may
be one or more Backup Nodes along the Backup Path. A Backup Node
may be the ingress, midpoint, or egress of the Backup Path. If
the Backup Path has only one Backup Node, then that Backup Node is
the ingress and egress of the Backup Path.
Measurement Units:
n/a
Issues:
None.
See Also:
Backup Path
3.4.5. Merge Node
Definition:
A node along the Primary Path where Backup Path terminates.
Discussion:
The Merge Node can be any node along the Primary Path except the
ingress node of the Primary Path. There can be multiple Merge
Nodes along a Primary Path. A Merge Node can be the egress node
for a single Backup Path or multiple Backup Paths. The Merge Node
must be the egress to the Backup Path. The Merge Node may also be
the egress of the Primary Path or Point of Local Repair (PLR).
Measurement Units:
n/a
Issues:
None.
See Also:
Primary Path
Backup Path
PLR
Failover
3.4.6. Primary Node
Definition:
A node along the Primary Path that is capable of Failover to a
redundant Standby Node.
Discussion:
The Primary Node may be used for Protection-Switching Systems that
provide Redundant Node Protection, such as VRRP and HA.
Measurement Units:
n/a
Issues:
None.
See Also:
Protection-Switching System Redundant Node Protection Standby Node
3.4.7. Standby Node
Definition:
A redundant node to a Primary Node; it forwards traffic along the
Primary Path upon Failure Detection of the Primary Node.
Discussion:
The Standby Node must be used for Protection-Switching Systems
that provide Redundant Node Protection, such as VRRP and HA. The
Standby Node must provide protection along the same Primary Path.
If the failover is to a Disjoint Path, then it is a Backup Node.
The Standby Node may be configured for 1:1 or N:1 protection.
The communication between the Primary Node and Standby Node may be
in-band or across an out-of-band State Control Interface. The
Standby Node may be geographically dispersed from the Primary
Node. When geographically dispersed, the number of hops of
separation may increase failover time.
The Standby Node may be passive or active. The Passive Standby
Node is not offered traffic and does not forward traffic until
Failure Detection of the Primary Node. Upon Failure Detection of
the Primary Node, traffic offered to the Primary Node is instead
offered to the Passive Standby Node. The Active Standby Node is
offered traffic and forwards traffic along the Primary Path while
the Primary Node is also active. Upon Failure Detection of the
Primary Node, traffic offered to the Primary Node is switched to
the Active Standby Node.
Measurement Units:
n/a
Issues:
None.
See Also:
Primary Node
State Control Interface
3.5. Benchmarks
3.5.1. Failover Packet Loss
Definition:
The amount of packet loss produced by a Failover Event until
Failover completes, where the measurement begins when the last
unimpaired packet is received by the Tester on the Protected
Primary Path and ends when the first unimpaired packet is received
by the Tester on the Backup Path.
Discussion:
Packet loss can be observed as a reduction of forwarded traffic
from the maximum forwarding rate. Failover Packet Loss includes
packets that were lost, reordered, or delayed. Failover Packet
Loss may reach 100% of the offered load.
Measurement Units:
Number of Packets
Issues:
None.
See Also:
Failover Event
Failover
3.5.2. Reversion Packet Loss
Definition:
The amount of packet loss produced by Reversion, where the
measurement begins when the last unimpaired packet is received by
the Tester on the Backup Path and ends when the first unimpaired
packet is received by the Tester on the Protected Primary Path.
Discussion:
Packet loss can be observed as a reduction of forwarded traffic
from the maximum forwarding rate. Reversion Packet Loss includes
packets that were lost, reordered, or delayed. Reversion Packet
Loss may reach 100% of the offered load.
Measurement Units:
Number of Packets
Issues:
None.
See Also:
Reversion
3.5.3. Failover Time
Definition:
The amount of time it takes for Failover to successfully complete.
Discussion:
Failover Time can be calculated using the Time-Based Loss Method
(TBLM), Packet-Loss-Based Method (PLBM), or Timestamp-Based Method
(TBM). It is RECOMMENDED that the TBM is used.
Measurement Units:
milliseconds
Issues:
None.
See Also:
Failover
Failover Time
Time-Based Loss Method (TBLM)
Packet-Loss-Based Method (PLBM)
Timestamp-Based Method (TBM)
3.5.4. Reversion Time
Definition:
The amount of time it takes for Reversion to complete so that the
Primary Path is restored as the Working Path.
Discussion:
Reversion Time can be calculated using the Time-Based Loss Method
(TBLM), Packet-Loss-Based Method (PLBM), or Timestamp-Based Method
(TBM). It is RECOMMENDED that the TBM is used.
Measurement Units:
milliseconds
Issues:
None.
See Also:
Reversion
Primary Path
Working Path
Reversion Packet Loss
Time-Based Loss Method (TBLM)
Packet-Loss-Based Method (PLBM)
Timestamp-Based Method (TBM)
3.5.5. Additive Backup Delay
Definition:
The amount of increased Forwarding Delay [4] resulting from data
traffic traversing the Backup Path instead of the Primary Path.
Discussion:
Additive Backup Delay is calculated using Equation 1 as shown
below:
(Equation 1)
Additive Backup Delay =
Forwarding Delay(Backup Path) -
Forwarding Delay(Primary Path)
Measurement Units:
milliseconds
Issues:
Additive Backup Latency may be a negative result. This is
theoretically possible but could be indicative of a sub-optimum
network configuration.
See Also:
Primary Path
Backup Path
Primary Path Latency
Backup Path Latency
3.6. Failover Time Calculation Methods
The following Methods may be assessed on a per-flow basis using at
least 16 flows spread over the routing table (using more flows is
better). Otherwise, the impact of a prefix-dependency in the
implementation of a particular protection technology could be missed.
However, the test designer must be aware of the number of packets per
second sent to each prefix, as this establishes sampling of the path
and the time resolution for measurement of Failover time on a per-
flow basis.
3.6.1. Time-Based Loss Method (TBLM)
Definition:
The method to calculate Failover Time (or Reversion Time) using a
time scale on the Tester to measure the interval of Failover
Packet Loss.
Discussion:
The Tester must provide statistics that show the duration of
failure on a time scale based on occurrence of packet loss on a
time scale. This is indicated by the duration of non-zero packet
loss. The TBLM includes failure detection time and time for data
traffic to begin traversing the Backup Path. Failover Time and
Reversion Time are calculated using the TBLM as shown in Equation
2:
(Equation 2)
(Equation 2a)
TBLM Failover Time = Time(Failover) - Time(Failover Event)
(Equation 2b)
TBLM Reversion Time = Time(Reversion) - Time(Restoration)
Where
Time(Failover) = Time on the tester at the receipt of the first
unimpaired packet at egress node after the backup path became the
working path
Time(Failover Event) = Time on the tester at the receipt of the
last unimpaired packet at egress node on the primary path before
failure
Measurement Units:
milliseconds
Issues:
None.
See Also:
Failover
Packet-Loss-Based Method
3.6.2. Packet-Loss-Based Method (PLBM)
Definition:
The method used to calculate Failover Time (or Reversion Time)
from the amount of Failover Packet Loss.
Discussion:
PLBM includes failure detection time and time for data traffic to
begin traversing the Backup Path. Failover Time can be calculated
using PLBM from the amount of Failover Packet Loss as shown below
in Equation 3. Note: If traffic is sent to more than 1
destination, PLBM gives the average loss over the measured
destinations.
(Equation 3)
(Equation 3a)
PLBM Failover Time =
(Number of packets lost / Offered Load rate) * 1000)
(Equation 3b)
PLBM Restoration Time =
(Number of packets lost / Offered Load rate) * 1000)
Units are packets/(packets/second) = seconds
Measurement Units:
milliseconds
Issues:
None.
See Also:
Failover Time-Based Loss Method
3.6.3. Timestamp-Based Method (TBM)
Definition:
The method to calculate Failover Time (or Reversion Time) using a
time scale to quantify the interval between unimpaired packets
arriving in the test stream.
Discussion:
The purpose of this method is to quantify the duration of failure
or reversion on a time scale based on the observation of
unimpaired packets. The TBM is calculated from Equation 2 with
the values obtained from the timestamp in the packet payload,
rather than from the Tester clock (which are used with the TBLM).
Unimpaired packets are normal packets that are not lost,
reordered, or duplicated. A reordered packet is defined in
Section 3.3 of [7]. A duplicate packet is defined in Section
3.3.5 of [4]. Unimpaired packets may be detected by checking a
sequence number in the payload, where the sequence number equals
the next expected number for an unimpaired packet. A sequence gap
or sequence reversal indicates impaired packets.
For calculating Failover Time, the TBM includes failure detection
time and time for data traffic to begin traversing the Backup
Path. For calculating Reversion Time, the TBM includes Reversion
Time and time for data traffic to begin traversing the Primary
Path.
Measurement Units:
milliseconds
Issues:
None.
See Also:
Failover
Failover Time
Reversion
Reversion Time
4. Security Considerations
Benchmarking activities as described in this memo are limited to
technology characterization using controlled stimuli in a laboratory
environment, with dedicated address space and the constraints
specified in the sections above.
The benchmarking network topology will be an independent test setup
and MUST NOT be connected to devices that may forward the test
traffic into a production network or misroute traffic to the test
management network.
Further, benchmarking is performed on a "black-box" basis, relying
solely on measurements observable external to the DUT/SUT.
Special capabilities SHOULD NOT exist in the DUT/SUT specifically for
benchmarking purposes. Any implications for network security arising
from the DUT/SUT SHOULD be identical in the lab and in production
networks.
5. References
5.1. Normative References
[1] Bradner, S., "The Internet Standards Process -- Revision 3", BCP
9, RFC 2026, October 1996.
[2] Bradner, S., "Benchmarking Terminology for Network
Interconnection Devices", RFC 1242, July 1991.
[3] Mandeville, R., "Benchmarking Terminology for LAN Switching
Devices", RFC 2285, February 1998.
[4] Poretsky, S., Perser, J., Erramilli, S., and S. Khurana,
"Terminology for Benchmarking Network-layer Traffic Control
Mechanisms", RFC 4689, October 2006.
[5] Bradner, S., "Key words for use in RFCs to Indicate Requirement
Levels", BCP 14, RFC 2119, March 1997.
[6] Poretsky, S., Imhoff, B., and K. Michielsen, "Terminology for
Benchmarking Link-State IGP Data Plane Route Convergence", RFC
6412, November 2011.
[7] Morton, A., Ciavattone, L., Ramachandran, G., Shalunov, S., and
J. Perser, "Packet Reordering Metrics", RFC 4737, November 2006.
[8] Nadas, S., Ed., "Virtual Router Redundancy Protocol (VRRP)
Version 3 for IPv4 and IPv6", RFC 5798, March 2010.
5.2. Informative References
[9] Pan, P., Ed., Swallow, G., Ed., and A. Atlas, Ed., "Fast Reroute
Extensions to RSVP-TE for LSP Tunnels", RFC 4090, May 2005.
[10] Nichols, K., Blake, S., Baker, F., and D. Black, "Definition of
the Differentiated Services Field (DS Field) in the IPv4 and
IPv6 Headers", RFC 2474, December 1998.
6. Acknowledgments
We would like thank the BMWG and particularly Al Morton and Curtis
Villamizar for their reviews, comments, and contributions to this
work.
Authors' Addresses
Scott Poretsky
Allot Communications
300 TradeCenter
Woburn, MA 01801
USA
Phone: + 1 508 309 2179
EMail: sporetsky@allot.com
Rajiv Papneja
Huawei Technologies
2330 Central Expressway
Santa Clara, CA 95050
USA
Phone: +1 571 926 8593
EMail: rajiv.papneja@huawei.com
Jay Karthik
Cisco Systems
300 Beaver Brook Road
Boxborough, MA 01719
USA
Phone: +1 978 936 0533
EMail: jkarthik@cisco.com
Samir Vapiwala
Cisco System
300 Beaver Brook Road
Boxborough, MA 01719
USA
Phone: +1 978 936 1484
EMail: svapiwal@cisco.com
ISO Plain Language
On this page
§1Introduction and Scope
RFC 6414 is the terminology document for benchmarking sub-IP protection mechanisms. The IP network layer provides route convergence to protect data traffic against planned and unplanned failures in the Internet, and fast convergence times are critical to maintaining reliable network connectivity and performance. Technologies that function at sub-IP layers can be enabled to give IP traffic further protection, by providing the failure recovery at the sub-IP layer so that the outage is not observed at the IP layer at all.
The sub-IP protection technologies the RFC names are High Availability (HA) stateful failover, Virtual Router Redundancy Protocol (VRRP), Automatic Protection Switching (APS) for SONET/SDH, Resilient Packet Ring (RPR) for Ethernet, and Fast Reroute for Multiprotocol Label Switching (MPLS-FRR).
Benchmarking terminology for IP-layer convergence was defined in RFC 6412, but different terminology and methodologies are needed for sub-IP protection mechanisms. The metrics are measured at the IP layer, so the results are always in reference to IP and independent of the specific protection mechanism being used. The purpose of this document is to provide a single terminology for benchmarking sub-IP protection mechanisms, so that different implementations of one mechanism can be compared, and so that different mechanisms can be compared with each other. The terminology can be applied to methodologies that benchmark with a single stream of traffic or with multiple streams, and the traffic flow may be unidirectional or bidirectional as the methodology indicates.
This RFC supplies the words for testing equipment that keeps traffic running when part of a network fails. The tests look at traffic at the IP layer, so two different protection mechanisms can be compared on the same terms.
§1.2The General Model
The RFC gives the sequence of events a protection benchmark measures. A Failover Event is when the Primary Path fails. Failure Detection is when that Failover Event is detected. Failover is when the Backup Path becomes the Working Path because of the Failover Event. Restoration is when the Primary Path recovers from the Failover Event. Reversion is optional, and is when the Primary Path becomes the Working Path again.
A benchmark must use a Protection-Switching System that consists of at least two Protection-Switching Nodes, an ingress node known as the Headend Node and an egress node known as the Merge Node. The system must include either a Primary Path and a Backup Path, or a Primary Node and a Standby Node. A Failover Event occurs along the Primary Path or at the Primary Node. The Working Path is the Primary Path before the Failover Event and the Backup Path after it. A Tester is set outside the two paths or nodes, as it sends and receives IP traffic along the Working Path. The Tester must record the IP packet sequence numbers, the departure time and the arrival time, so that Failover Time, Additive Latency, Packet Reordering, Duplicate Packets and Reversion Time can be measured. The Tester may be a single device or a test system.
Five models may be used. Link Protection covers a Failover Event on the link between two nodes along the Primary Path. Node Protection covers a Failover Event at a node along the Primary Path. Path Protection covers link or node failures for multiple hops along the Primary Path. Local Link Protection protects a link between two nodes without using a Backup Node, an example being SONET APS. High Availability Protection protects a Primary Node with a redundant Standby Node, with State Control provided between the two nodes; failure of the Primary Node is detected at the sub-IP layer to force traffic to switch to the Standby Node, which has state maintained for zero or minimal packet loss.
The RFC fixes the order of events a test measures: something fails, the equipment notices, traffic moves to the backup route, the original route comes back, and traffic may then move back to it. The test equipment sits outside the network and records packet numbers and arrival times.
§3.1Paths and Kinds of Protection
A Path is a unidirectional sequence of nodes and links in the sub-IP layer: an ingress node that forwards IP packets into the DUT or SUT, nodes in between that forward data frames using sub-IP information, and an egress node that outputs sub-IP frames as IP packets. A path is unidirectional, so the reverse direction is a separate path, and a bidirectional path is benchmarked as two independent unidirectional paths. Examples are the SONET/SDH path and the label switched path for MPLS.
Three path roles matter for protection. The Working Path is the path the DUT or SUT is currently using to forward packets. The Primary Path is the preferred point-to-point path, and it is the Working Path before a Failover Event. A Protected Primary Path is a Primary Path that has a Backup Path, and it must include at least one Protection-Switching Node. The Backup Path exists to carry data traffic only if a Failover Event occurs on a Primary Path; it must be created before the Failover Event, and it may be a Standby Backup Path established beforehand or a Dynamic Backup Path established when the event occurs. Backup Paths come in dedicated recovery forms, 1+1 or 1:1, shared 1:N, and associated shared M:N.
Two further terms describe how paths relate to each other. Disjoint Paths are a pair of paths that share no common link or node other than the ingress and egress. The Point of Local Repair (PLR) is a node along the Primary Path that can perform Failover and is also the ingress node for a Backup Path protecting another node or link; there may be several PLRs along a Primary Path, and the PLR can be any node on it except the egress node. A Shared Risk Link Group (SRLG) is a set of links that share the same physical or logical risk, and the group fails as a whole when the shared resource fails.
Five kinds of protection build on those paths. Link Protection signals a Backup Path to at least one Backup Node to protect against failure of interfaces and links along a Primary Path. Node Protection signals a Backup Path to protect against failure of interfaces, links and nodes, and it also provides Link Protection. Path Protection signals a Backup Path to provide protection along the entire Primary Path, covering every node and link on it. Local Link Protection is a Backup Path that is a redundant path between two nodes and does not use a Backup Node, as provided by systems such as SONET APS. Redundant Node Protection is a Protection-Switching System with a Primary Node protected by a Standby Node along the Primary Path, as provided by VRRP and HA; the failover may be stateful, with state exchanged in-band or over an out-of-band State Control Interface, and the Standby Node may be active or passive. The Backup Span is the number of hops used by a Backup Path, obtained by counting the nodes along it.
The RFC names the parts: the route traffic normally takes, the standby route, the node that decides to switch, and the kinds of protection built from those. It also names the group of links that share one physical or logical risk, so two routes that look independent can be recognised as likely to fail together.
- Link ProtectionA Backup Path protects against failure of interfaces and links along the Primary Path.
- Node ProtectionA Backup Path protects against failure of interfaces, links and nodes, and also gives Link Protection.
- Path ProtectionA Backup Path protects the entire Primary Path, covering every node and link on it.
- Local Link ProtectionA redundant path between two nodes that uses no Backup Node, as in SONET APS.
- Redundant Node ProtectionA Primary Node protected by a Standby Node, as in VRRP and HA.
§3.3Protection Switching Events
A Protection-Switching System is a DUT or SUT that is capable of Failure Detection and Failover from a Primary Path to a Backup Path or Standby Node when a Failover Event occurs. It includes the mechanisms for both Failure Detection and Failover.
A Failover Event is a planned or unplanned action in the network that results in a change in the path that data traffic traverses, such as link failure or router failure. Routing changes are Convergence Events in the sense of RFC 6412 and are not Failover Events, which keeps Failover Events at sub-IP layers. Failover may take place at the PLR or at the ingress, and when it is at the ingress it is generally on a path disjoint from the ingress to the egress.
Failure Detection is the process of identifying at a sub-IP layer a Failover Event at a Primary Node or along the Primary Path. It happens at the Primary Node or the ingress node of the Primary Path, using a sub-IP mechanism such as detection of a link down event or a timeout for receipt of a control packet. A failure may be completely isolated, may affect a set of links that share a single SRLG such as a port with many sub-interfaces, or may affect multiple links that are not part of an SRLG.
Failover is the process of switching data traffic from the protected Primary Path to the Backup Path once the failure has been detected. Failover to a Backup Path provides Link Protection, Node Protection or Path Protection. Failover is complete when Packet Loss, Out-of-order Packets and Duplicate Packets are no longer observed; Forwarding Delay may continue to be observed.
Restoration is the state in which the Primary Path has recovered from the Failover Event but is not yet forwarding packets, because the Backup Path remains the Working Path. Reversion is the state in which the Primary Path has become the Working Path and is forwarding packets again. A Protection-Switching System may or may not support Reversion, and if it does, Reversion must occur after Restoration. A potential problem with Reversion is the discontinuity in end-to-end delay when the Forwarding Delays along the Primary Path and the Backup Path differ, which can cause Out-of-order Packets, Duplicate Packets and increased Jitter.
The RFC separates the moment the network changes from the moment the equipment reacts. A change caused by a link or router failure is a failover event; a routing change is not. Detection happens at the primary node or at the ingress, and the switch to the backup counts as finished only once no packets are lost, reordered or duplicated.
- Primary Path is the Working Path start
- Backup Path is the Working Path
- Primary Path recovered, Backup Path still working
- Primary Path is the Working Path again
| From | To | Event |
|---|---|---|
| Primary Path is the Working Path | Backup Path is the Working Path | Failover Event, Failure Detection, Failover |
| Backup Path is the Working Path | Primary Path recovered, Backup Path still working | Restoration |
| Primary Path recovered, Backup Path still working | Primary Path is the Working Path again | Reversion (optional) |
§3.6Benchmarks and Failover Time Methods
Five benchmarks are defined. Failover Packet Loss is the amount of packet loss produced by a Failover Event until Failover completes; the measurement begins when the last unimpaired packet is received by the Tester on the Protected Primary Path and ends when the first unimpaired packet is received on the Backup Path. It includes packets that were lost, reordered or delayed, and it may reach 100% of the offered load. Reversion Packet Loss is the same measurement taken across the return to the Primary Path. Failover Time is the amount of time it takes for Failover to complete successfully, and Reversion Time is the amount of time it takes for Reversion to complete so that the Primary Path is restored as the Working Path. Both are measured in milliseconds. Additive Backup Delay is the increased Forwarding Delay that results from traffic traversing the Backup Path instead of the Primary Path, computed as the Forwarding Delay on the Backup Path minus the Forwarding Delay on the Primary Path. It may be a negative result, which is theoretically possible but could be indicative of a sub-optimum network configuration.
Three methods calculate Failover Time and Reversion Time, and the RFC recommends the Timestamp-Based Method (TBM). The Time-Based Loss Method (TBLM) uses a time scale on the Tester to measure the interval of Failover Packet Loss, indicated by the duration of non-zero packet loss; it includes failure detection time and the time for data traffic to begin traversing the Backup Path, and it is calculated as Time(Failover) minus Time(Failover Event). The Packet-Loss-Based Method (PLBM) takes the number of packets lost, divides it by the Offered Load rate and multiplies by 1000 to obtain milliseconds; if traffic is sent to more than one destination, it gives the average loss over the measured destinations. The Timestamp-Based Method (TBM) uses the timestamp in the packet payload, rather than the Tester clock, to quantify the interval between unimpaired packets arriving in the test stream. An unimpaired packet is one that is not lost, reordered or duplicated, and it may be detected by checking that a sequence number in the payload equals the next expected number; a sequence gap or a sequence reversal indicates impaired packets.
The methods may be assessed on a per-flow basis using at least 16 flows spread over the routing table, and using more flows is better. Otherwise a prefix-dependency in the implementation of a particular protection technology could be missed. The test designer must be aware of the number of packets per second sent to each prefix, because that sets the sampling of the path and the time resolution for measuring Failover Time on a per-flow basis.
The RFC reports how many packets were lost and how long the switch took, in milliseconds. Three ways of timing it are offered, and the RFC recommends the one that reads the timestamp inside each packet, because that measures the gap between good packets as the network user sees it.
| Method | Where the timing comes from | What it reports |
|---|---|---|
| Time-Based Loss Method (TBLM) | The Tester clock and the duration of non-zero packet loss | Failover Time as Time(Failover) minus Time(Failover Event) |
| Packet-Loss-Based Method (PLBM) | Packets lost and the Offered Load rate | Milliseconds, averaged over destinations if more than one is used |
| Timestamp-Based Method (TBM) THIS RFC | The timestamp inside the packet payload | The interval between unimpaired packets arriving in the test stream |
§4Security Considerations
Benchmarking activities as described in this memo are limited to technology characterization using controlled stimuli in a laboratory environment, with dedicated address space. The benchmarking network topology must be an independent test setup and must not be connected to devices that may forward the test traffic into a production network or misroute traffic to the test management network.
Benchmarking is performed on a black-box basis, relying solely on measurements observable external to the DUT or SUT. Special capabilities should not exist in the DUT or SUT specifically for benchmarking purposes, so that any security implications arising from the device should be identical in the lab and in production networks.
Run the tests on a separate network with its own address space, and do not connect that network to production equipment. Measure only what an outside observer can see, and do not add benchmarking-only features to the equipment under test.