RFC 7102 INFORMATIONAL ROUTING · IOT · NETWORKS

LLN Routing Terms: Terms Used in Routing for Low-Power and Lossy Networks

The shared vocabulary for routing in networks of tiny, battery-powered devices.

On rfc-editor.org ↗
PUBLISHED
January 2014
AUTHORS
JP. Vasseur
STREAM
IETF
TYPICAL SENSOR RAM
A few kilobytes
TYPICAL SENSOR FLASH MEMORY
A few dozens of kilobytes
TYPICAL DATA RATES
A few kilobits to a few hundred kilobits per second
TYPICAL MICROCONTROLLER
8-, 16- or 32-bit
LINK TECHNOLOGIES NAMED
IEEE 802.15.4 and low-power Wi-Fi
ROUTING PROTOCOL
RPL, an IPv6 routing protocol for LLNs
DOI
10.17487/RFC7102

RFC text

Contents
Original text · RFC Editor View on rfc-editor.org ↗
Internet Engineering Task Force (IETF)                       JP. Vasseur
Request for Comments: 7102                           Cisco Systems, Inc.
Category: Informational                                     January 2014
ISSN: 2070-1721


         Terms Used in Routing for Low-Power and Lossy Networks

Abstract

   This document provides a glossary of terminology used in routing
   requirements and solutions for networks referred to as Low-Power and
   Lossy Networks (LLNs).  An LLN is typically composed of many embedded
   devices with limited power, memory, and processing resources
   interconnected by a variety of links.  There is a wide scope of
   application areas for LLNs, including industrial monitoring, building
   automation (e.g., heating, ventilation, air conditioning, lighting,
   access control, fire), connected home, health care, environmental
   monitoring, urban sensor networks, energy management, assets
   tracking, and refrigeration.

Status of This Memo

   This document is not an Internet Standards Track specification; it is
   published for informational purposes.

   This document is a product of the Internet Engineering Task Force
   (IETF).  It represents the consensus of the IETF community.  It has
   received public review and has been approved for publication by the
   Internet Engineering Steering Group (IESG).  Not all documents
   approved by the IESG are a candidate for any level of Internet
   Standard; see Section 2 of RFC 5741.

   Information about the current status of this document, any errata,
   and how to provide feedback on it may be obtained at
   http://www.rfc-editor.org/info/rfc7102.

Copyright Notice

   Copyright (c) 2014 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (http://trustee.ietf.org/license-info) in effect on the date of
   publication of this document.  Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document.  Code Components extracted from this document must
   include Simplified BSD License text as described in Section 4.e of
   the Trust Legal Provisions and are provided without warranty as
   described in the Simplified BSD License.

Table of Contents

   1. Introduction ....................................................2
   2. Terminology .....................................................3
   3. Security Considerations .........................................7
   4. Acknowledgements ................................................7
   5. Informative References ..........................................7

1.  Introduction

   This document provides a glossary of terminology used in routing
   requirements and solutions for networks referred to as Low-Power and
   Lossy Networks (LLNs).

   LLNs are typically composed of many embedded devices with limited
   power, memory, and processing resources interconnected by a variety
   of links, such as IEEE 802.15.4 or low-power Wi-Fi.  There is a wide
   scope of application areas for LLNs, including industrial monitoring,
   building automation (heating, ventilation, air conditioning,
   lighting, access control, fire), connected home, health care,
   environmental monitoring, urban sensor networks, energy management,
   assets tracking, and refrigeration.

   Since these applications are usually highly specific (for example,
   industrial automation, building automation, etc.), it is not uncommon
   to see a number of disparate terms used to describe the same device
   or functionality.  Thus, in order to avoid confusion or
   discrepancies, this document specifies the common terminology to be
   used in all ROLL working group documents.  The terms defined in this
   document are used in [RFC5548], [RFC5673], [RFC5826], and [RFC5867].

   Terminology specific to a particular application is out of the scope
   of this document.

   It is expected that all routing documents defining requirements or
   specifying solutions for LLN will use the common terminology
   specified in this document.  This document should be listed as an
   informative reference.

2.  Terminology

   Actuator: A field device that controls a set of equipment.  For
      example, an actuator might control and/or modulate the flow of a
      gas or liquid, control electricity distribution, perform a
      mechanical operation, etc.

   AMI: Advanced Metering Infrastructure.  Makes use of Smart Grid
      technologies.  A canonical Smart Grid application is smart-
      metering.

   Channel: Radio frequency sub-band used to transmit a modulated signal
      carrying packets.

   Channel Hopping: A procedure by which field devices synchronously
      change channels during operation.

   Commissioning Tool: Any physical or logical device temporarily added
      to the network for the express purpose of setting up the network
      and device operational parameters.  The commissioning tool can
      also be temporarily added to the LLN for scheduled or unscheduled
      maintenance.

   Closed Loop Control: A procedure whereby a device controller controls
      an actuator based on input information sensed by one or more field
      devices.

   Controller: A field device that can receive sensor input and
      automatically change the environment in the facility by
      manipulating digital or analog actuators.

   DA: Distribution Automation.  Part of Smart Grid.  Encompasses
      technologies for maintenance and management of electrical
      distribution systems.

   DAG: Directed Acyclic Graph.  A directed graph with no directed
      cycles (a graph formed by a collection of vertices and directed
      edges where each edge connects one vertex to another, such that
      there is no way to start at some vertex v and follow a sequence of
      edges that eventually loops back to vertex v again).

   Data sink: A device that collects data from nodes in an LLN.

   Downstream: Data direction traveling from outside of the LLN (e.g.,
      traffic coming from a LAN, WAN, or the Internet) via an LLN Border
      Router (LBR), or in general, "deeper" in the Directed Acyclic
      Graph computed by the routing protocol.

   Field Device: A field device is a physical device placed in the
      network's operating environment (e.g., plant, urban area, or
      home).  Field devices include sensors and actuators as well as
      routers and Low-Power and Lossy Network Border Routers (LBRs).  A
      field device is usually (but not always) a device with constrained
      CPU, memory footprint, storage capacity, bandwidth, and sometimes
      power (battery operated).  At the time of writing, for the sake of
      illustration, a typical sensor or actuator would have a few
      Kilobytes of RAM, a few dozens of Kilobytes of ROM/Flash memory, a
      8-/16-/32-bit microcontroller, and communication capabilities
      ranging from a few kbits/s to a few hundred kbits/s.  Although
      continuous improvement of hardware and software technologies is
      expected, such devices will likely continue to be seen as
      resource-constrained devices compared to computers and routers
      used in the rest of the Internet.

   Flash Memory: non-volatile memory that can be re-programmed.

   FMS: Facility Management System.  A global term applied across all
      the vertical designations within a building, including heating,
      ventilation, and air conditioning (also referred to as HVAC),
      fire, security, lighting, and elevator control.

   HART: Highway Addressable Remote Transducer.  A group of
      specifications for industrial process and control devices
      administered by the HART Foundation (see [HART]).  The latest
      version for the specifications is HART7, which includes the
      additions for WirelessHART.

   HVAC: Heating, Ventilation, and Air Conditioning.  A term applied to
      mechanisms used to maintain the comfort level of an internal
      space.

   ISA: International Society of Automation.  An ANSI accredited
      standards-making society.  ISA100 is an ISA committee whose
      charter includes defining a family of standards for industrial
      automation.  [ISA100.11a] is a working group within ISA100 that is
      working on a standard for monitoring and non-critical process-
      control applications.

   LAN: Local Area Network.

   LBR: Low-Power and Lossy Network Border Router.  A device that
      connects the Low-Power and Lossy Network to another routing domain
      such as a LAN, a WAN, or the Internet where a different routing
      protocol may be in operation.  The LBR acts as a routing device
      and may possibly host other functions such as data collector or
      aggregator.

   LLN: Low-Power and Lossy Network.  Typically composed of many
      embedded devices with limited power, memory, and processing
      resources interconnected by a variety of links, such as IEEE
      802.15.4 or low-power Wi-Fi.  There is a wide scope of application
      areas for LLNs, including industrial monitoring, building
      automation (HVAC, lighting, access control, fire), connected home,
      health care, environmental monitoring, urban sensor networks,
      energy management, assets tracking, and refrigeration.

   MP2P: Multipoint-to-Point.  Used to describe a particular traffic
      pattern (e.g., MP2P flows collecting information from many nodes
      flowing upstream towards a collecting sink or an LBR).

   MAC: Medium Access Control.  Refers to algorithms and procedures used
      by the data link layer to coordinate use of the physical layer.

   Non-Sleepy Node: A node that always remains in a fully powered-on
      state (i.e., always awake) where it has the capability to perform
      communication.

   Open Loop Control: A process whereby a plant operator manually
      manipulates an actuator over the network where the decision is
      influenced by information sensed by field devices.

   PER: Packet Error Rate.  A ratio of the number of unusable packets
      (not received at all or received in error, even after any
      applicable error correction has been applied) to the total number
      of packets that would have been received in the absence of errors.

   P2P: Point To Point.  Refers to traffic exchanged between two nodes
      (regardless of the number of hops between the two nodes).

   P2MP: Point-to-Multipoint.  Refers to traffic between one node and a
      set of nodes.  This is similar to the P2MP concept in Multicast or
      MPLS Traffic Engineering ([RFC4461]and [RFC4875]).  A common use
      case for the Routing Protocol for Low-Power and Lossy Networks
      (RPL) involves P2MP flows from or through a DAG root outward
      towards other nodes contained in the DAG.

   RAM: Random Access Memory.  A volatile memory.

   RFID: Radio Frequency IDentification.

   ROM: Read-Only Memory.

   ROLL: Routing Over Low-Power and Lossy Networks.

   RPL: An IPv6 Routing Protocol for Low-Power and Lossy Networks that
      provides a mechanism whereby multipoint-to-point traffic from
      devices inside the LLN towards a central control point as well as
      point-to-multipoint traffic from the central control point to the
      devices inside the LLN are supported.  RPL also supports point-to-
      point traffic between any arbitrary nodes in the LLN.

   RPL Domain: A collection of RPL routers under the control of a single
      administration.  The boundaries of routing domains are defined by
      network management by setting some links to be exterior, or inter-
      domain, links.

   Schedule: An agreed execution, wake-up, transmission, reception,
      etc., timetable between two or more field devices.

   Sensor: A device that measures a physical quantity and converts it to
      an analog or digital signal that can be read by a program or a
      user.  Sensed data can be of many types: electromagnetic (e.g.,
      current, voltage, power, or resistance), mechanical (e.g.,
      pressure, flow, liquid density, or humidity), chemical (e.g.,
      oxygen or carbon monoxide), acoustic (e.g., noise or ultrasound),
      etc.

   Sleepy Node: A node that may sometimes go into a sleep mode (i.e., go
      into a low-power state to conserve power) and temporarily suspend
      protocol communication.  When not in sleep mode, the sleepy node
      is in a fully powered-on state where it has the capability to
      perform communication.

   Smart Grid: A broad class of applications to network and automate
      utility infrastructure.

   Timeslot: A fixed time interval that may be used for the transmission
      or reception of a packet between two field devices.  A timeslot
      used for communications is associated with a slotted-link.

   Upstream: Data direction traveling from the LLN via the LBR to
      outside of the LLN (LAN, WAN, or Internet) or generally closer to
      the root of the DAG computed by the routing protocol.

   WAN: Wide Area Network.

3.  Security Considerations

   Since this document specifies terminology and does not specify new
   procedures or protocols, it raises no new security issues.

4.  Acknowledgements

   The authors would like to thank Christian Jacquenet, Tim Winter,
   Pieter De Mil, David Meyer, Mukul Goyal, and Abdussalam Baryun for
   their valuable feedback.

5.  Informative References

   [HART]    HART Communication Foundation, <http://www.hartcomm.org>.

   [ISA100.11a]
             ISA, "Wireless systems for industrial automation: Process
             control and related applications", ISA 100.11a, May 2008,
             <http://www.isa.org/Community/
             SP100WirelessSystemsforAutomation>.

   [RFC4461] Yasukawa, S., Ed., "Signaling Requirements for Point-to-
             Multipoint Traffic-Engineered MPLS Label Switched Paths
             (LSPs)", RFC 4461, April 2006.

   [RFC4875] Aggarwal, R., Ed., Papadimitriou, D., Ed., and S. Yasukawa,
             Ed., "Extensions to Resource Reservation Protocol - Traffic
             Engineering (RSVP-TE) for Point-to-Multipoint TE Label
             Switched Paths (LSPs)", RFC 4875, May 2007.

   [RFC5548] Dohler, M., Ed., Watteyne, T., Ed., Winter, T., Ed., and D.
             Barthel, Ed., "Routing Requirements for Urban Low-Power and
             Lossy Networks", RFC 5548, May 2009.

   [RFC5673] Pister, K., Ed., Thubert, P., Ed., Dwars, S., and T.
             Phinney, "Industrial Routing Requirements in Low-Power and
             Lossy Networks", RFC 5673, October 2009.

   [RFC5826] Brandt, A., Buron, J., and G. Porcu, "Home Automation
             Routing Requirements in Low-Power and Lossy Networks", RFC
             5826, April 2010.

   [RFC5867] Martocci, J., Ed., De Mil, P., Riou, N., and W. Vermeylen,
             "Building Automation Routing Requirements in Low-Power and
             Lossy Networks", RFC 5867, June 2010.

Author's Address

   JP. Vasseur
   Cisco Systems, Inc.
   1414 Massachusetts Avenue
   Boxborough, MA  01719
   US

   EMail: jpv@cisco.com

ISO Plain Language

On this page
PROBLEMNetworks of sensors and actuators are built for wildly different industries, and each industry tends to invent its own name for the same device, so documents about routing them use different words for the same thing.
MECHANISMThe RFC fixes a common set of terms for the routing working group to use, covering the devices, the network shape, the direction of traffic and the way the devices sleep and wake.
WHAT IT ISThe document is a glossary, not a protocol. It defines no procedures and raises no security issues of its own, and it is expected that later routing documents will cite it.

§1Why a Shared Word List

The document provides a glossary of the terminology used in routing requirements and solutions for networks referred to as Low-Power and Lossy Networks. Such a network is typically composed of many embedded devices with limited power, memory and processing resources, interconnected by a variety of links such as IEEE 802.15.4 or low-power Wi-Fi.

There is a wide scope of application areas, including industrial monitoring, building automation for heating, ventilation, air conditioning, lighting, access control and fire, connected home, health care, environmental monitoring, urban sensor networks, energy management, assets tracking, and refrigeration. Since these applications are usually highly specific, it is not uncommon to see a number of disparate terms used to describe the same device or functionality. To avoid confusion or discrepancies, the document specifies the common terminology to be used in all the documents of the routing working group, and the terms it defines are already used in the routing requirement documents for urban, industrial, home and building networks.

Terminology specific to a particular application is out of scope. The expectation is that all routing documents defining requirements or specifying solutions for these networks will use the common terminology, and that this document should be listed as an informative reference.

Every industry calls the same little box a different name. Once you are writing about how such devices route their messages, you need one set of names, and this RFC is that set.

§2The Devices and the Network

A field device is a physical device placed in the network's operating environment, such as a plant, an urban area or a home. Field devices include sensors and actuators as well as routers and border routers, and are usually, though not always, constrained in processor, memory footprint, storage capacity, bandwidth and sometimes power. For illustration, a typical sensor or actuator would have a few kilobytes of RAM, a few dozens of kilobytes of read-only or flash memory, an 8-, 16- or 32-bit microcontroller, and communication capabilities ranging from a few kilobits per second to a few hundred kilobits per second. Even as hardware improves, such devices are likely to keep looking resource-constrained next to the computers and routers used in the rest of the internet.

A sensor measures a physical quantity and converts it into an analogue or digital signal that can be read by a program or a person, of many kinds: electromagnetic, such as current, voltage, power or resistance, mechanical, such as pressure, flow, liquid density or humidity, chemical, such as oxygen or carbon monoxide, and acoustic, such as noise or ultrasound. An actuator is a field device that controls a set of equipment, for example modulating the flow of a gas or liquid, controlling electricity distribution, or performing a mechanical operation. A controller is a field device that can receive sensor input and automatically change the environment in the facility by manipulating digital or analogue actuators. A data sink is a device that collects data from nodes in the network.

The border router of a low-power and lossy network connects that network to another routing domain, such as a local area network, a wide area network or the internet, where a different routing protocol may be in operation. It acts as a routing device and may also host other functions such as a data collector or aggregator. The routing structure itself is a directed acyclic graph: a collection of vertices and directed edges where each edge connects one vertex to another, such that there is no way to start at some vertex and follow a sequence of edges that eventually loops back to where you started. RPL is the IPv6 routing protocol for these networks. It supports multipoint-to-point traffic from devices inside the network towards a central control point, point-to-multipoint traffic from that control point back out to the devices, and point-to-point traffic between any two nodes. An RPL domain is a collection of RPL routers under the control of a single administration, with the boundaries of routing domains set by network management marking some links as exterior or inter-domain links.

The vocabulary covers the sensors that read the world, the actuators that change it, the controllers that connect the two, the little routers in between, and the border router that joins the whole thing to the internet.

WHERE A LOW-POWER AND LOSSY NETWORK SITS
  1. ApplicationWhat the sensor or actuator is actually for
  2. Low-power and lossy networkField devices joined by links such as IEEE 802.15.4
  3. Border routerConnects the network to another routing domain
  4. LAN, WAN or the internetThe rest of the world, with a different routing protocol
THE CORE VOCABULARY OF THE GLOSSARY
  • Field deviceA physical device in the operating environment, usually with very little memory, processor and power.
  • SensorMeasures a physical quantity and turns it into a signal a program can read.
  • ActuatorControls equipment, such as the flow of a gas or an electric supply.
  • ControllerTakes sensor input and changes the environment by driving actuators.
  • Border routerConnects the network to another routing domain, and may collect data as well.
  • Data sinkThe device that collects data from the nodes in the network.

§2Direction, Traffic Patterns and Sleeping Devices

Direction is defined relative to the network. Upstream is the data direction travelling from inside the network out through the border router to a local area network, a wide area network or the internet, or generally closer to the root of the directed acyclic graph computed by the routing protocol. Downstream is the opposite: data travelling from outside the network in through the border router, or generally deeper into the graph.

Three traffic patterns are named. Point to point is traffic exchanged between two nodes, whatever the number of hops between them. Point-to-multipoint is traffic between one node and a set of nodes, a concept much like the one used in multicast or in MPLS traffic engineering; a common use of RPL involves point-to-multipoint flows from or through the root of the graph outwards towards the other nodes. Multipoint-to-point describes a traffic pattern such as flows collecting information from many nodes and flowing upstream towards a collecting sink or a border router.

Because the devices have so little power, they sleep. A sleepy node may sometimes go into a sleep mode, a low-power state that conserves power, and temporarily suspend protocol communication; when it is not asleep it is fully powered on and able to communicate. A non-sleepy node is always fully powered on and always able to communicate. Around this sit the radio terms. A channel is a radio frequency sub-band used to transmit a modulated signal carrying packets, and channel hopping is the procedure by which field devices synchronously change channels while operating. A timeslot is a fixed time interval that may be used for the transmission or reception of a packet between two field devices, and a timeslot used for communications is associated with a slotted link. A schedule is an agreed execution, wake-up, transmission or reception timetable between two or more field devices. The packet error rate is the ratio of the number of unusable packets, whether not received at all or received in error after any applicable error correction, to the total number that would have been received without errors.

The same terms are used for which way data is going and for how the radios share the air. Nodes spend most of their time asleep, so the routing has to work with devices that are only occasionally listening.

UPSTREAM AND DOWNSTREAM, AS DEFINED IN RFC 7102
Upstreamfield-device → border-routerData travelling out of the network, and generally closer to the root of the routing graph.
OPPOSITE OF
Downstreamborder-router → field-deviceData travelling into the network from outside, and generally deeper into the routing graph.

§2The Vocabulary of Particular Industries

Several terms belong to the application areas rather than to routing. Advanced metering infrastructure uses smart grid technologies, and a canonical smart grid application is smart metering. Distribution automation is part of the smart grid and encompasses technologies for the maintenance and management of electrical distribution systems. A smart grid is a broad class of applications that network and automate utility infrastructure. The facility management system is a global term applied across all the vertical designations within a building, including heating, ventilation and air conditioning, fire, security, lighting and elevator control. The Highway Addressable Remote Transducer group of specifications covers industrial process and control devices, and its latest version, HART7, includes the additions for WirelessHART. The International Society of Automation is an accredited standards-making society, and ISA100 is one of its committees, whose charter includes defining a family of standards for industrial automation, with a working group inside it working on a standard for monitoring and non-critical process-control applications.

Two control models are distinguished. Under closed loop control, a device controller controls an actuator based on input information sensed by one or more field devices. Under open loop control, a plant operator manually manipulates an actuator over the network, with the decision influenced by information sensed by field devices. A commissioning tool is any physical or logical device temporarily added to the network for the express purpose of setting up the network and the device operational parameters, and it can also be added temporarily for scheduled or unscheduled maintenance. The document also names radio frequency identification, the medium access control algorithms used by the data link layer to coordinate use of the physical layer, and the memory types the devices use: RAM is volatile, ROM is read-only, and flash memory is non-volatile but can be re-programmed.

Some of the words belong to a particular industry: what a smart meter is called, what a plant operator does differently from a controller, and what a maintenance laptop is called when it is plugged in for an afternoon.

§3Security

The RFC is one paragraph long on security. Since the document specifies terminology and does not specify new procedures or protocols, it raises no new security issues.

A word list cannot introduce a security problem, because it introduces no behaviour. The document says exactly that and stops there.

§6References